Archives of Electrical Engineering (Nov 2021)

The effect of closed loop control on diagnostic indices in different faults of squirrel cage induction motor

  • Nourelhouda Bouabid,
  • Mohamed-Amine Moussa,
  • Yassine Maouche,
  • Abdelmalek Khezzar

DOI
https://doi.org/10.24425/aee.2021.138271
Journal volume & issue
Vol. vol. 70, no. No 4
pp. 943 – 958

Abstract

Read online

The aim of this work is to study the influence of closed loop control on diagnostic indices of both broken bar and mixed air-gap eccentricity fault indices of the squirrel cage induction motor drive. The present work is focused on the direct stator current isd signal analysis, which is independent of torque load when the induction motor is controlled by an indirect control field. The fault signatures are on the line extracted from the direct stator current signal using the discrete Fourier transformation (DFT). The formula of the measured direct stator current at both conditions is determined by the transfer function of the current loop. The obtained results show that the current loop corresponds to a low pass filter and can reduce the magnitude of diagnostic indicators which lead to wrong evaluation of the fault. Simulation and experiments were carried out in order to confirm the theoretical analysis.

Keywords