Journal of Anesthesia, Analgesia and Critical Care (Mar 2024)
Pulmonary shunt in critical care: a practical approach with clinical scenarios
Abstract
Abstract Background Pulmonary shunt refers to the passage of venous blood into the arterial blood system bypassing the alveoli-blood gas exchange. Pulmonary shunt is defined by a drop in the physiologic coupling of lung ventilation and lung perfusion. This may consequently lead to respiratory failure. Main body The pulmonary shunt assessment is often neglected. From a mathematical point of view, pulmonary shunt can be assessed by estimating the degree of mixing between oxygenated and deoxygenated blood. To compute the shunt, three key components are analyzed: the oxygen (O2) content in the central venous blood before gas exchange, the calculated O2 content in the pulmonary capillaries after gas exchange, and the O2 content in the arterial system, after the mixing of shunted and non-shunted blood. Computing the pulmonary shunt becomes of further importance in patients on extracorporeal membrane oxygenation (ECMO), as arterial oxygen levels may not directly reflect the gas exchange of the native lung. Conclusion In this review, the shunt analysis and its practical clinical applications in different scenarios are discussed by using an online shunt simulator. Graphical Abstract
Keywords