Chinese Neurosurgical Journal (Mar 2021)

Safety and efficacy of stent-assisted coiling for acutely ruptured wide-necked intracranial aneurysms: comparison of LVIS stents with laser-cut stents

  • Gaici Xue,
  • Qiao Zuo,
  • Xiaoxi Zhang,
  • Haishuang Tang,
  • Rui Zhao,
  • Qiang Li,
  • Yibin Fang,
  • Pengfei Yang,
  • Bo Hong,
  • Yi Xu,
  • Qinghai Huang,
  • Jianmin Liu

DOI
https://doi.org/10.1186/s41016-021-00237-1
Journal volume & issue
Vol. 7, no. 1
pp. 1 – 10

Abstract

Read online

Abstract Background To compare the safety and efficacy of LVIS stent-assisted coiling with those of laser-cut stent-assisted coiling for the treatment of acutely ruptured wide-necked intracranial aneurysms. Methods Patients with acutely ruptured wide-necked intracranial aneurysms treated with LVIS stent-assisted coiling (LVIS stent group) and laser-cut stent-assisted coiling (laser-cut stent group) were retrospectively reviewed from January 2014 to December 2017. Propensity score matching was used to adjust for potential differences in age, sex, aneurysm location, aneurysm size, neck width, Hunt-Hess grade, and modified Fisher grade. Perioperative procedure-related complications and clinical and angiographic follow-up outcomes were compared. Univariate and multivariate analyses were performed to determine the associations between procedure-related complications and potential risk factors. Results A total of 142 patients who underwent LVIS stent-assisted coiling and 93 patients who underwent laser-cut stent-assisted coiling were enrolled after 1:2 propensity score matching. The angiographic follow-up outcomes showed that the LVIS stent group had a slightly higher complete occlusion rate and lower recurrence rate than the laser-cut stent group (92.7% vs 80.6%; 3.7% vs 9.7%, P = 0.078). The clinical outcomes at discharge and follow-up between the two groups demonstrated no significant differences (P = 0.495 and P = 0.875, respectively). The rates of intraprocedural thrombosis, postprocedural thrombosis, postoperative early rebleeding, and procedure-related death were 0.7% (1/142), 1.4% (2/142), 2.8% (4/142), and 2.1% (3/142) in the LVIS stent group, respectively, and 4.3% (4/93), 2.2% (2/93), 1.1% (1/93), and 3.2% (3/93) in the laser-cut stent group, respectively (P = 0.082, 0.649, 0.651, and 0.683). Nevertheless, the rates of overall procedure-related complications and intraprocedural rupture in the LVIS stent group were significantly lower than those in the laser-cut stent group (5.6% vs 14.0%, P = 0.028; 0.7% vs 6.5%, P = 0.016). Multivariate analysis showed that laser-cut stent-assisted coiling was an independent predictor for overall procedure-related complications (OR = 2.727, P = 0.037); a history of diabetes (OR = 7.275, P = 0.027) and other cerebrovascular diseases (OR = 8.083, P = 0.022) were independent predictors for ischemic complications, whereas none of the factors were predictors for hemorrhagic complications. Conclusions Compared with laser-cut stent-assisted coiling, LVIS stent-assisted coiling for the treatment of acutely ruptured wide-necked intracranial aneurysms could reduce the rates of overall procedure-related complications and intraprocedural rupture.

Keywords