Annals of Pediatric Cardiology (Jan 2014)

Transcatheter closure of hypertensive ductus with amplatzer post infarction muscular VSD occluder after percutaneous retrieval of embolized amplatzer duct occluder

  • Milind S Phadke,
  • Satish Karur,
  • Prafulla G Kerkar

DOI
https://doi.org/10.4103/0974-2069.132481
Journal volume & issue
Vol. 7, no. 2
pp. 126 – 129

Abstract

Read online

Transcatheter closure of a large hypertensive patent ductus arteriosus is challenging with scant data about it. Even more challenging is retrieval of an embolized Amplatzer duct occluder. We report successful closure of a 12 mm large ductus with the Amplatzer muscular VSD occluder (post myocardial infarction) after percutaneous retrieval of the embolized, largest available, 16/14 mm Amplatzer duct occluder.