Abstract
The thermal performances of a designed double-channel slot-hole water aluminium heat exchanger for a powerful electronic component and water copper heat exchanger, available in the market, Titan in a composition both made system of water cooling, and unlocked are explored experimentally. The pictorial dependences of tapped power on medial value of temperature of the simulator of a heat flow are given. Is shown, that the slot-hole heat exchanger allows to obtain higher values of tapped power at identical temperature of the simulator. At temperature of the simulator of a heat-generating component +60°C with in the made system of cooling the tapped power is incremented with 112 up to 172 W, and in unlocked - with 234 up to 307,4 W.