Brazilian Journal of Cardiovascular Surgery (Jun 2008)

CPAP at 10 cm H2O during cardiopulmonary bypass does not improve postoperative gas exchange CPAP de 10 cmH2O durante a circulação extracorpórea não melhora a troca gasosa pós-operatória

  • Luciana Castilho de Figueiredo,
  • Sebastião Araújo,
  • Rosângela Cristina S. Abdala,
  • Abrão Abdala,
  • Cristina Aparecida Veloso Guedes

DOI
https://doi.org/10.1590/S0102-76382008000200010
Journal volume & issue
Vol. 23, no. 2
pp. 209 – 215

Abstract

Read online

OBJECTIVE: To compare postoperative (PO) pulmonary gas exchange indexes in patients submitted to myocardial revascularization (MR) with or without the application of continuous positive airway pressure (CPAP) during cardiopulmonary bypass (CPB). METHODS: Thirty adult patients submitted to MR with CPB between March and September 2005 were randomly allocated to two groups: CPAP (n=15), patients that received CPAP at 10 cmH2O during CPB, and control (n=15), patients that didn't receive CPAP. PaO²/FiO2 and P(A-a)O2 were analyzed at four moments: Pre (just before CPB, with FiO2=1.0 ); Post (30min post-CPB, with FiO2=1.0); immediate PO period (12h post-surgery, with FiO2=0.4 by using a Venturi® facial mask) and first PO day (24h post-surgery, with FiO2=0.5 by a facial mask). RESULTS: PaO2/FiO2 and P(A-a)O2 tend to get significantly worst as time elapsed during the postoperative period in both groups, but no differences were observed between them at any moment. When PaO2/FiO2 was subdivided into three categories, a greater prevalence of patients with values between 200 mmHg and 300mmHg were observed in CPAP group only at moment Post (30min post-CPB; p = 0.02). CONCLUSION: CPAP at 10cmH2O administered during CPB, although had lightly improved PaO2/FiO2 at 30 minutes post-CPB, had no significant sustained effect on postoperative pulmonary gas exchange. We concluded that in patients submitted to MR, application of 10 cmH2O CPAP does not improve postoperative pulmonary gas exchange.OBJETIVO: Comparar os índices de trocas gasosas no pós-operatório de pacientes submetidos a revascularização do miocárdio (RM) que receberam ou não pressão positiva contínua nas vias aéreas (CPAP) durante a circulação extracorpórea (CEC). MÉTODOS: Trinta pacientes adultos submetidos a RM com CEC no período de março a setembro de 2005 foram alocados aleatoriamente em dois grupos: CPAP (n=15), pacientes que utilizaram CPAP a 10 cmH2O durante a CEC, e controle (n=15), pacientes que não utilizaram CPAP. Foram analisados a PaO2/FiO2 e o P(A-a)O2 em quatro momentos: Pré (logo antes da CEC, com FiO2 = 1,0); Pós (30min pós-CEC, com FiO2 = 1,0); PO imediato (12h após a cirurgia, com FiO2 = 0,4, utilizando máscara facial) e 1º PO (24 horas após a cirurgia, com FiO2 = 0,5, utilizando máscara facial). RESULTADOS: A PaO2/FiO2 e o P(A-a)O2 mostraram piora significativa no decorrer do tempo dentro de cada grupo, porém sem diferenças significativas entre os grupos em nenhum momento. Quando a PaO2/FiO2 foi subdividida em três categorias, foi observada maior prevalência de pacientes do grupo CPAP com valores entre 200 mmHg e 300 mmHg (p=0,02) apenas no momento Pós (30min pós-CEC). CONCLUSÃO: O uso de CPAP de 10 cmH2O durante a CEC, muito embora tenha resultado em melhores valores na PaO2/FiO2 30 minutos pós-CEC, não resultou em benefícios duradouros nas trocas gasosas durante o PO. Nós concluímos que, em pacientes submetidos a RM, a aplicação de CPAP 10 cmH2O não melhora significativamente as trocas gasosas pulmonares no pós-operatório.

Keywords