Brazilian Journal of Cardiovascular Surgery (Sep 2008)

Avaliação de oxigenador de membrana infantil em ovinos Evaluation of infant membrane oxygenator in sheep

  • Renata Geron Finoti,
  • Domingo Marcolino Braile,
  • Ulisses Alexandre Croti,
  • Marcos Aurélio Barboza de Oliveira,
  • Moacir Fernandes de Godoy,
  • João Carlos Ferreira Leal,
  • Sebastião Rodrigues Policarpo,
  • Marden Leonardi Lopes

DOI
https://doi.org/10.1590/S0102-76382008000300012
Journal volume & issue
Vol. 23, no. 3
pp. 358 – 364

Abstract

Read online

OBJETIVO: Analisar a segurança e a eficácia de um novo oxigenador de membrana denominado OXM -1500. MÉTODOS: No período de maio de 2005 a setembro de 2006, foram estudados seis ovinos da raça Santa Inês, sendo cinco machos e uma fêmea, com peso corpóreo médio de 14,1 (±5) kg, superfície corpórea de 0,6 (±0,2) m² e idade média de 3,8 (±1,5) meses. Todos foram submetidos a circulação extracorpórea (CEC) com avaliação nos tempos 10, 30, 60, 120, 180 e 240 minutos, obtendo-se os valores de taxa de transferência de oxigênio (TTO2) e de taxa de transferência de gás carbônico (TTCO2), hemoglobina sérica (HBS) e livre (HBL), plaquetometria, leucometria e taxa de transferência de calor. RESULTADOS: Houve adequadas TTO2 e TTCO2. A lesão da maioria dos elementos figurados do sangue foi insignificante, sem alterações dos níveis de HBS, HBL, plaquetas e o número de leucócitos diminuíram com o tempo. A troca de calor foi efetiva (p OBJECTIVE: To analyze the security and efficacy of a new membrane oxygenator, the so-called OXM - 1500. METHODS: From May 2005 to September 2006, six sheep of Santa Inês breed (five male and one female, respectively) were studied. The average body weight was 14.1 (±5) kg, body surface 0.6 (±0.2) m² and a mean age 3.8 (±1.5) months. All of them were submitted to extracorporeal circulation (CEC) with evaluation at 10, 30, 60, 120, 180 and 240 minutes. The following values were obtained: values of oxygen transference (TTO2) and carbon dioxide transference (TTCO2), haemoglobin (HBS) and free haemoglobin (HBL), the score of platelets and of leucocytes, and heat transference rate. RESULTS: TTO2 and TTCO2 were adequate. Lesion of the majority formed blood elements was insignificant; there no modifications in HBS, HBL levels; platelets and leucocytes decreased over time. Heat exchange was effective (p < 0.05). CONCLUSIONS: The membrane OXM - 1500 infant oxygenator, tested in sheep, showed adequate oxygenation capacity, CO2 removal capacity, and small alteration of haemoglobin and platelets without significant decrease of leucocytes, as expected. Heat exchanger connected to the oxygenator was efficient in temperature changes.

Keywords