Pesquisa Veterinária Brasileira (Dec 2014)

Evaluation of bursal lymphoid depletion: comparison between the conventional histology method and digital lymphocyte depletion evaluation system

  • Carlos T.P. Salle,
  • Lucas B. Moraes,
  • Francielli C. Zimermann,
  • Luiz C.B. Fallavena,
  • Fernando S. Osório,
  • Felipe O. Salle,
  • Daiane Carvalho,
  • Hamilton L.S. Moraes

DOI
https://doi.org/10.1590/S0100-736X2014001300002
Journal volume & issue
Vol. 34, no. suppl 1
pp. 7 – 10

Abstract

Read online

Abstract: Fifty-five bursa of Fabricius (BF) were evaluated by optical microscopy for three different avian histopathologists (H1, H3 and H4) to determine the degree of lymphoid depletion. One histologist evaluated the same slides at two different times (H1 and H2) with four-months interval between the observations. The same BFs were evaluated using the system of Digital Lymphocyte Depletion Evaluation (ADDL), being performed by three differents operators of the system, not histopathologists. The results showed was a significant difference between the histopathologists and between the scores established by the same expert (H1 and H2). However, there were not significant differences between the scores with the ADDL system, obtained using ADDL. The results make clear the fragility of the subjective lymphocyte depletion score classification by the traditional histologic method, while the ADDL system proves to be more appropriated for the assessment of the lymphoid loss in the BF.

Keywords