Journal of Orthopaedic Surgery and Research (Dec 2023)
Perioperative peri-implant fracture after osteosynthesis for geriatric femoral pertrochanteric fracture with the linear compression integrated screw intramedullary nail system (INTERTAN™): a retrospective study
Abstract
Abstract Background Osteosynthesis for geriatric femoral pertrochanteric fractures using the linear compression integrated screw intramedullary nail system (INTERTAN™) has become popular. Nonetheless, cases of perioperative peri-implant fractures have been reported following this surgical technique. The factors responsible for this complication remain unclear. Therefore, we investigated perioperative peri-implant fracture risk factors and incidence, as well as overall outcomes, using the INTERTAN™ system for geriatric femoral pertrochanteric fractures. Methods We retrospectively reviewed 98 consecutive patients with geriatric femoral pertrochanteric fractures after INTERTAN™ fixation, with at least a 12-month follow-up period between May 2020 and April 2022 at a single medical institute. The patients’ demographic characteristics, fracture pattern, quality of reduction, quality of fixation, nail length, morphology of the femur, and perioperative complications were recorded and analyzed. Results Among the 98 patients, 92 achieved union during follow-up. Twelve perioperative peri-implant fractures (12.2%) were recorded, all of which occurred during or within 1 month of osteosynthesis. Except for one patient who underwent re-osteosynthesis, the others underwent nonoperative treatment, and all achieved union. Multiple regression analysis revealed morphology of the femur with low-lesser trochanter width (odds ratio (OR) 0.532, 95% confidence interval (CI) 0.33–0.86, p = 0.01) to be the only factor contributing to perioperative peri-implant fractures. When the Youden index was used, the optimal cut-off value was 20.2 mm of low-lesser trochanter width. Low-lesser trochanter width < 20.2 mm was found to be a potential factor causing perioperative peri-implant fractures (OR 17.81, 95% CI 1.67–19.76, p = 0.017). Conclusions Morphology of the femur with a low-lesser trochanter width smaller than 20.2 mm was found to be the only potential contributor to perioperative peri-implant fractures when using INTERTAN™ for geriatric femoral pertrochanteric fractures. Care should be taken during osteosynthesis, focusing not only on the fracture site but also on the femoral cortex around the implant. Although perioperative peri-implant fractures were observed within one month following osteosynthesis, the majority of these cases were effectively treated without surgical intervention.
Keywords