Sensors (Feb 2023)
Measurement of Trunk Movement during Sit-to-Stand Motion Using Laser Range Finders: A Preliminary Study
Abstract
The sit-to-stand (STS) motion evaluates physical functions in frail older adults. Mounting sensors or using a camera is necessary to measure trunk movement during STS motion. Therefore, we developed a simple measurement method by embedding laser range finders in the backrests and seats of chairs that can be used in daily life situations. The objective of this study was to validate the performance of the proposed measurement method in comparison with that of the optical motion capture (MoCap) system during STS motion. The STS motions of three healthy young adults were simultaneously measured under seven conditions using a chair with embedded sensors and the optical MoCap system. We evaluated the waveform similarity, absolute error, and relationship of the trunk joint angular excursions between these measurement methods. The experimental results indicated high waveform similarity in the trunk flexion phase regardless of STS conditions. Furthermore, a strong relationship was observed between the two measurement methods with respect to the angular excursion of the trunk flexion. Although the angular excursion of the trunk extension exhibited a large error, the developed chair with embedded sensors evaluated trunk flexion during the STS motion, which is a characteristic of frail older adults.
Keywords