Indian Heart Journal (Dec 2018)

Coronary sinus as a site for stable temporary atrial pacing to tide over premature ventricular complex–triggered recurrent ventricular fibrillation in a patient with severe left ventricular dysfunction after coronary bypass surgery

  • Aniruddha Vyas,
  • Yash Lokhandwala

Journal volume & issue
Vol. 70
pp. S483 – S485

Abstract

Read online

Use of atrial pacing has been known, yet underutilized tool for effective temporary pacing whenever needed early after cardiac surgery. The reasons may be frequent failures of epicardial wires (fixed over atria intra-operative) leading to loss of capture. Endocardial atrial pacing sites for temporary pacing are unstable and hence continuous pacing with acceptable thresholds is impossible. We describe a case of ischemic cardiomyopathy and severe left ventricle systolic dysfunction who required atrial pacing post coronary artery bypass grafting (CABG) surgery for around 48–72 hours starting 4th day post operation when he had multiple episodes of ventricular fibrillation (VF) needing many defibrillation shocks. VF episodes were triggered by premature ventricular complexes (PVC) falling on as R on T. Episodes were refractory to anti-arrhythmic drugs and general anesthesia. These PVC were successfully overdriven by atrial pacing by fluoroscopically placing pacing lead in coronary sinus. This led to complete suppression of PVC induced VF for next 48–72 hours while the antiarrhythmic drugs were continued. Subsequently the patient was discharged in stable state. Atrial pacing, though quite valuable during the post-operative period after cardiac surgery, is underutilized, especially when pacing through surgically placed epicardial wire fails. This report is helpful in drawing attention towards coronary sinus (CS) as an alternate site for achieving stable, temporary atrial pacing during the post-operative period. This site can also be utilized for short term dual chamber pacing if required in post-operative state using transvenous CS site for atrial pacing and intraoperatively placed epicardial wire for ventricular pacing.