Arabian Journal of Chemistry (Jul 2021)

Extraction of penicillin G from aqueous solution using a membrane contactor: Numerical investigation

  • Yan Cao,
  • Afrasyab Khan,
  • Shaheen Sarkar,
  • Ahmad B. Albadarin

Journal volume & issue
Vol. 14, no. 7
p. 103230

Abstract

Read online

In the current study, the treatment of pharmaceutical wastewater containing penicillin G treatment using a hollow fibre membrane contactor was investigated. A mathematical model based on the finite element method was developed. The extraction was performed using Shellsol TK as organic solvent containing 5% Aliquat 336. The effect of feed pH, flow rate and temperature were examined for the extraction of penicillin G from aqueous solution. The results showed that there is reasonable good agreement between experimental data and modelling values. It was found that increasing temperature from 10 °C to 30 °C increases the penicillin G extraction from 33% to 54%. Also, penicillin G extraction was decreased from 34.7% to 25.1% with increasing pH from 5.5 to 6.5 while it grew to 45.8% when the pH of feed solution was 7. Furthermore, the results showed the diffusive flux is favourable for the system and penicillin G extraction but the convective flux has negative impact on the system in terms of penicillin G extraction. It was concluded that a hollow fibre membrane contactor has the potential for use in wastewater treatment through it is important to improve diffusive flux in the system to enhance penicillin G extraction.

Keywords