STAR Protocols (Dec 2022)

An fMRI protocol for administering liquid incentives to human participants

  • Debbie M. Yee,
  • Jennifer L. Crawford,
  • Todd S. Braver

Journal volume & issue
Vol. 3, no. 4
p. 101707

Abstract

Read online

Summary: This protocol describes the materials and approaches for administering liquid incentives to human participants during fMRI scanning. We first describe preparation of the liquid solutions (e.g., neutral solution and saltwater) and liquid delivery setups. We then detail steps to connect the setups to the computer-controlled syringe pump in the MRI control room, followed by procedures for testing the syringe pump dispensing a liquid bolus during the task. Description of custom software and required adapters for implementing the liquid setup are included.For complete details on the use and execution of this protocol, please refer to Yee et al. (2021). : Publisher’s note: Undertaking any experimental protocol requires adherence to local institutional guidelines for laboratory safety and ethics.

Keywords