Química Nova (Jan 2012)

Estudo da emissão por fluorescência de ultravioleta na quantificação de um inibidor de corrosão do tipo sal de amônio quaternário em água

  • Herllaine de Almeida Rangel,
  • Fábio Merçon

DOI
https://doi.org/10.1590/S0100-40422012000700002
Journal volume & issue
Vol. 35, no. 7
pp. 1287 – 1293

Abstract

Read online

Quaternary ammonium salts are the corrosion inhibitors most frequently used by the oil industry. In this study, the ultraviolet fluorescence technique was evaluated for the analysis of a quaternary ammonium salt in water as a corrosion inhibitor. The comparison with standard salt showed that an alkyl aryl quaternary ammonium salt is the main fluorophore, with emission maxima at 306 and 593 nm. The best instrumental parameters were: width of excitation and emission slits of 10 and 15 nm, respectively, and scan rate of 10 nm min-1. The presence of aromatic compounds and biocides affects the analysis of corrosion inhibitors.

Keywords