Biomedicines (Jul 2023)

A Comparative Analysis of Strain and 2D Shear Wave Elastography in the Diagnosis of Autoimmune Thyroiditis in Pediatric Patients

  • Cristina Mihaela Roi,
  • Andreea Borlea,
  • Monica Simina Mihuta,
  • Corina Paul,
  • Dana Stoian

DOI
https://doi.org/10.3390/biomedicines11071970
Journal volume & issue
Vol. 11, no. 7
p. 1970

Abstract

Read online

This paper aims to assess the usefulness of shear-wave elastography (SWE) and strain elastography (SE) for identifying and monitoring thyroid gland changes in children diagnosed with chronic autoimmune thyroiditis (CAT). Our study included 77 children between the ages of six and eighteen. Of these, 45 were diagnosed with CAT, while 32 had no thyroid pathology. Following a clinical examination and laboratory tests, an ultrasound was carried out, and then a SE (using a Hitachi Preirus machine) and SWE (using an Aixplorer Mach 30, Supersonic imagine, France) were performed in the same session. The median thyroid elastic index (EI) in the CAT group was 13.8 (13.3–17) kPa compared to 10.1 (9.3–11.2) kPa in healthy children (p p 1 (Se = 82.2%, Sp = 87.5%, PPV = 90.2%, and NPV = 77.8%, AUROC = 0.850), while using SWE, the optimal cut-off value for predicting the presence of CAT in children was >12 kPa (Se = 88.9%, Sp = 93.7%, PPV = 95.2%, and NPV = 85.5%, AUROC = 0.943). Both techniques are useful for measuring thyroid tissue elasticity, and their diagnostic accuracy and reliability are comparable.

Keywords