CVIR Endovascular (Feb 2022)

Cardiac solution for a vascular scenario!

  • Jamal Moosavi,
  • Somaye Ahmadi,
  • Ata Firouzi,
  • Parham Sadeghipour,
  • Bahram Mohebbi,
  • Omid Shafe,
  • Azin Alizadeasl,
  • Sanaz Asadian,
  • Mehran Hoseini

DOI
https://doi.org/10.1186/s42155-021-00280-0
Journal volume & issue
Vol. 5, no. 1
pp. 1 – 5

Abstract

Read online

Abstract Background Ascending aortic pseudoaneurysms (AAPs) constitute a rare, albeit potentially dangerous, condition that occurs in up to 13% of patients after cardiac or aortic surgeries. For patients with a history of cardiac surgery, repeat thoracotomy poses additive risks. The high morbidity and mortality rates associated with the surgical management of AAPs have led to the development of transcatheter approaches. Case report We report a case of AAP percutaneous closure at the site of aortic cannulation with an ASO device in a post-CABG 65-year-old man, who refused surgery. Conclusion The use of the Amplatzer Atrial Septal Defect Occluder (ASO) device represents an acceptable alternative to surgery in treatment of Ascending aortic pseudoaneurysms.