PLoS ONE (Jan 2016)

Development, Validation, and Field-Testing of an Instrument for Clinical Assessment of HIV-Associated Neuropathy and Neuropathic Pain in Resource-Restricted and Large Population Study Settings.

  • Yohannes W Woldeamanuel,
  • Peter R Kamerman,
  • Demetri G A Veliotes,
  • Tudor J Phillips,
  • David Asboe,
  • Marta Boffito,
  • Andrew S C Rice

DOI
https://doi.org/10.1371/journal.pone.0164994
Journal volume & issue
Vol. 11, no. 10
p. e0164994

Abstract

Read online

HIV-associated sensory peripheral neuropathy (HIV-SN) afflicts approximately 50% of patients on antiretroviral therapy, and is associated with significant neuropathic pain. Simple accurate diagnostic instruments are required for clinical research and daily practice in both high- and low-resource setting. A 4-item clinical tool (CHANT: Clinical HIV-associated Neuropathy Tool) assessing symptoms (pain and numbness) and signs (ankle reflexes and vibration sense) was developed by selecting and combining the most accurate measurands from a deep phenotyping study of HIV positive people (Pain In Neuropathy Study-HIV-PINS). CHANT was alpha-tested in silico against the HIV-PINS dataset and then clinically validated and field-tested in HIV-positive cohorts in London, UK and Johannesburg, South Africa. The Utah Early Neuropathy Score (UENS) was used as the reference standard in both settings. In a second step, neuropathic pain in the presence of HIV-SN was assessed using the Douleur Neuropathique en 4 Questions (DN4)-interview and a body map. CHANT achieved high accuracy on alpha-testing with sensitivity and specificity of 82% and 90%, respectively. In 30 patients in London, CHANT diagnosed 43.3% (13/30) HIV-SN (66.7% with neuropathic pain); sensitivity = 100%, specificity = 85%, and likelihood ratio = 6.7 versus UENS, internal consistency = 0.88 (Cronbach alpha), average item-total correlation = 0.73 (Spearman's Rho), and inter-tester concordance > 0.93 (Spearman's Rho). In 50 patients in Johannesburg, CHANT diagnosed 66% (33/50) HIV-SN (78.8% neuropathic pain); sensitivity = 74.4%, specificity = 85.7%, and likelihood ratio = 5.29 versus UENS. A positive CHANT score markedly increased of pre- to post-test clinical certainty of HIV-SN from 43% to 83% in London, and from 66% to 92% in Johannesburg. In conclusion, a combination of four easily and quickly assessed clinical items can be used to accurately diagnose HIV-SN. DN4-interview used in the context of bilateral feet pain can be used to identify those with neuropathic pain.