Journal of Functional Biomaterials (Aug 2023)

Use of Dichlorodimethylsilane to Produce Polydimethylsiloxane as a Substitute for Vitreous Humour: Characteristics and In Vitro Toxicity

  • Diba Grace Auliya,
  • Ulfa Fauziah,
  • Vira Fuji Arini,
  • Soni Setiadji,
  • Fitrilawati Fitrilawati,
  • Arief Sjamsulaksan Kartasasmita,
  • Risdiana Risdiana

DOI
https://doi.org/10.3390/jfb14080425
Journal volume & issue
Vol. 14, no. 8
p. 425

Abstract

Read online

Polydimethylsiloxane (PDMS) is a substitute for vitreous humour in vitreoretinal surgery and is usually produced from octamethylcyclotetrasiloxane (D4). In Indonesia, both commercial PDMS and D4 are limited and expensive. Dichlorodimethylsilane (DCMS) can be an alternative to produce PDMS. DCMS is cheaper and easier to obtain than D4. However, more extra effort is needed in order to produce PDMS from DCMS. Therefore, this study aimed to produce PDMS from DCMS by varying the ratio of DCMS precursor to dichloromethane (DCM) solvent at ratios of 1:1 and 1:4 through the hydrolysis–condensation method under neutral conditions. The PDMS produced had medium- (2.06 Pa·s) and high viscosity (3.59 Pa·s), with densities ranging from 0.96 to 0.99 g/mL. The refractive index was 1.4034–1.4036 and surface tension was 21 × 10−3 N/m, while they were able to transmit ~100% visible light, which were similar values to the commercial PDMS characteristics. PDMS samples were characterized using IR and NMR spectroscopy, which confirmed they were of PDMS type. The most optimum DCMS:DCM ratio was 1:1 due to the medium-viscosity PDMS type that could be produced. The in vitro HET–CAM toxicity test showed that samples were non-irritant, similar to PDMS produced from D4. PDMS from DCMS was non-toxic and ready to be used as a vitreous humuor substitution.

Keywords