Data in Brief (Jun 2022)

Dataset on full ultrasonic guided wavefield measurements of a CFRP plate with fully bonded and partially debonded omega stringer

  • Kudela Pawel,
  • Radzienski Maciej,
  • Moix-Bonet Maria,
  • Willberg Christian,
  • Lugovtsova Yevgeniya,
  • Bulling Jannis,
  • Tschöke Kilian,
  • Moll Jochen

Journal volume & issue
Vol. 42
p. 108078

Abstract

Read online

The fourth dataset dedicated to the Open Guided Waves platform [1] presented in this work aims at a carbon fiber composite plate with an additional omega stringer at constant temperature conditions. The dataset provides full ultrasonic guided wavefields. Two types of signals were used for guided wave excitation, namely chirp signal and tone-burst signal. The chirp signal had a frequency range of 20–500 kHz. The tone-burst signals had a form of sine modulated by Hann window with 5 cycles and carrier frequencies 16.5 kHz, 50 kHz, 100 kHz, 200 kHz, 300 kHz. The piezoceramic actuator used for this purpose was attached to the center of the stringer side surface of the core plate. Three scenarios are provided with this setup: (1) wavefield measurements without damage, (2) wavefield measurements with a local stringer debond and (3) wavefield measurements with a large stringer debond. The defects were caused by impacts performed from the backside of the plate. As result, the stringer feet debonds locally which was verified with conventional ultrasound measurements.

Keywords