Journal of Multidisciplinary Healthcare (Jul 2021)

Zero-Heat-Flux and Esophageal Temperature Monitoring in Orthopedic Surgery: An Observational Study

  • Munday J,
  • Higgins N,
  • Jones L,
  • Vagenas D,
  • Van Zundert A,
  • Keogh S

Journal volume & issue
Vol. Volume 14
pp. 1819 – 1827

Abstract

Read online

Judy Munday,1,2 Niall Higgins,1,3 Lee Jones,1,4 Dimitrios Vagenas,4 André Van Zundert,1,5,6 Samantha Keogh1,3 1School of Nursing & Centre for Healthcare Transformation, Faculty of Health, Queensland University of Technology, Kelvin Grove, QLD, Australia; 2Department of Health and Nursing Science, Faculty of Health and Sports Sciences, University of Agder, Grimstad, Norway; 3Royal Brisbane and Women’s Hospital, Herston, QLD, Australia; 4Research Methods Group, Institute of Health and Biomedical Innovation (IHBI), Faculty of Health, Queensland University of Technology, Kelvin Grove, QLD, Australia; 5Department of Anaesthesia and Perioperative Medicine, Royal Brisbane and Women’s Hospital, Brisbane, QLD, Australia; 6School of Medicine, The University of Queensland, Brisbane, Australia & Queensland University of Technology, Brisbane, QLD, AustraliaCorrespondence: Judy MundaySchool of Nursing & Centre for Healthcare Transformation, Queensland University of Technology, Rm 529, Level 5, N Block, Kelvin Grove, QLD, 4059, AustraliaTel +61 73138 8209Fax +61 3138 3814Email [email protected]: Perioperative hypothermia prevention requires regular, accurate, and consistent temperature monitoring. Zero-heat-flux (ZHF) thermometry offers a non-invasive, measurement method that can be applied across all surgical phases. The purpose of this study was to measure agreement between the zero-heat-flux device and esophageal monitoring, sensitivity, and specificity to detect hypothermia and patient acceptability amongst patients undergoing upper and lower limb orthopedic surgery.Patients and Methods: This prospective, observational study utilized Bland–Altman analysis and Lin’s concordance coefficient to measure agreement between devices, sensitivity and specificity to detect hypothermia and assessed patient acceptability amongst 30 patients between December 2018 and June 2019.Results: Bias was observed between devices via Bland Altman, with bias dependent on actual temperature. The mean difference ranged from − 0.16°C at 34.9°C (where the mean of ZHF was lower than the esophageal device) to 0.46°C at 37.25°C (where the mean of ZHF was higher than esophageal device), with 95% limits of agreement (max) upper LOA = 0.80 to 1.41, lower LOA = − 1.12 to − 0.50. Seventy-five percentage of zero-heat-flux measurements were within 0.5°C of esophageal readings. Patient acceptability was high; 96% (n=27) stated that the device was comfortable.Conclusion: ZHF device achieved lesser measurement accuracy with core (esophageal) temperature compared to earlier findings. Nonetheless, due to continuous capability, non-invasiveness and patient reported acceptability, the device warrants further evaluation.Title Registration: The study was registered at www.ANZCTR.org.au (reference: ACTRN12619000842167).Keywords: perioperative, thermoregulation, thermometry, sensitivity, specificity

Keywords