Buildings (Nov 2023)
In-Situ Test and Numerical Simulation of Anchoring Performance of Embedded Rock GFRP Anchor
Abstract
Compared to traditional steel reinforcement, GFRP anchors demonstrate outstanding mechanical performance and corrosion resistance, and so they are an ideal substitute for steel reinforcement in anti-floating projects. Based on finite element software, a 3D axisymmetric calculation model of GFRP anti-floating anchors in medium-weathered granite was established in this paper. Combined with the in-situ ultimate pull-out tests, the bonding anchoring performance and bearing characteristics between the anchor body, anchoring mortar, and rock–soil mass were analyzed. The research findings indicated that the cohesive bonding elements exhibited a high degree of conformity in defining the interface contact relationship of the GFRP anti-floating anchor anchoring system. The axial force of the GFRP anti-floating anchor body is “attenuated” along the depth direction, and there was a critical value of anchoring length; under the same conditions, the reasonable anchoring length should be 3.5~5.0 m. All the anchors in the in-situ tests exhibited interfacial shear slip failure between the anchor body and the anchor mortar, with an average maximum load of 450 kN, which is consistent with the maximum failure load of the simulated anchors. Compared to a load of 50 kN, the maximum stress of the anchor mortar increased by 50% under a load of 450 kN. The displacement variation of the surrounding rock–soil mass showed a decreasing trend from the inside to the outside and from the top to the bottom. The research results provided valuable references for the optimization design of GFRP anti-floating anchors.
Keywords