Nuclear Engineering and Technology (Feb 2020)

H.B. Robinson-2 pressure vessel dosimetry benchmark: Deterministic three-dimensional analysis with the TORT transport code

  • Roberto Orsi

Journal volume & issue
Vol. 52, no. 2
pp. 448 – 455

Abstract

Read online

The H.B. Robinson Unit 2 (HBR-2) pressure vessel dosimetry benchmark is an in- and ex-Reactor Pressure Vessel (RPV) neutron dosimetry benchmark based on experimental data from the HBR-2 reactor, a 2300-MW PWR designed by Westinghouse and put in operation in March 1971, openly available through the SINBAD Database at OECD/NEA data Bank. The goals of the present work were to carry out three-dimensional (3D) fixed source transport calculations in both Cartesian (X,Y,Z) and cylindrical (R,θ,Z) geometries by using the TORT-3.2 discrete ordinates code on very detailed 3D HBR-2 geometrical models and to test the latest broad-group coupled (47 neutron groups + 20 photon groups) working cross section libraries in FIDO-ANISN format with same structure as BUGLE-96, such as BUGJEFF311.BOLIB, BUGENDF70.BOLIB and BUGLE-B7. The results obtained with all the cited libraries were satisfactory and are here reported and compared. Keywords: HBR-2 benchmark, TORT, Discrete-ordinates, BUGLE-96, BUGJEFF311.BOLIB, BUGLE-B7