Abstract

Read online

Background: Among many advances in the treatment of rotator cuff tears, arthroscopic augmentation techniques with patches of various biological and synthetic graft materials have been introduced to reinforce the repair. However, structural and functional outcomes after patch augmentation vary, and reinforcing the tendon healing remains a challenge. The aim of this study was to evaluate clinical and radiologic outcomes 1 year after arthroscopic posterosuperior (PS) rotator cuff repair with bioabsorbable patch augmentation. Methods: From October 2014 to December 2017, all patients with PS rotator cuff tears undergoing arthroscopic repair with patch augmentation using a resorbable, biologically derived poly-4-hydroxybutyrate patch (Biofiber; Wright, Memphis, TN, USA) were enrolled in this study. Only full-thickness PS lesions with ≥1 of the following tear patterns were augmented with a patch and were the subject of this study: large U- and L-shaped tear, transtendinous tear, delamination, and fraying of the bursal layer. Patients were examined preoperatively and at 1 year postoperatively with a standardized examination protocol and magnetic resonance imaging (MRI). Results: Sixteen patients were included in this study; 1 patient was lost to follow-up. One patient only underwent clinical follow-up. We detected 1 repair failure (6.7%) with dislocation of the lateral-row anchors on computed tomography scanning at 3 months postoperatively. MRI was performed in 14 patients after 1 year; in all of them, the cuff repair was intact. The Sugaya tendon integrity score was 1.7 ± 0.9. The Constant-Murley score improved from 44 to 89 points (P < .001). Muscular strength improved in the supraspinatus (from 2.6 to 4.8), infraspinatus (from 3.2 to 4.9), and subscapularis (from 4 to 4.9) (all P < .001). Overall, patient satisfaction was high (3.6 ± 0.6). Discussion: This small-sized case series is the first to prospectively assess clinical and radiologic outcomes after patch augmentation of PS rotator cuff tears using bioabsorbable poly-4-hydroxybutyrate patches. Good to excellent structural and functional outcomes were observed with a low retear rate (6.7%) and good tendon integrity on 1-year postoperative MRI, and the graft did not cause any complications. The use of bioabsorbable patches could be beneficial when unfavorable PS tear patterns are encountered in which a stable repair of the full tendon thickness at its insertion is otherwise difficult to reach.

Keywords