The analysis and performance evaluation of a harmonic reduction strategy of a non-overlap winding wound rotor synchronous machine is conducted in this paper. The harmonic reduction strategy utilizes phase-shifts between coil currents to reduce sub- and higher-order harmonics. The design is performed on a 3 MW wound rotor synchronous machine with a 16/18 pole/slot combination. The application results in a lowered torque ripple and an increased efficiency of the designed machine. The manufacturing and testing of a 3 kW prototype to ascertain the effectiveness of the design is also presented. The practical measurements correlate successfully with the theoretical results.