Cancer Imaging (Jul 2019)

Diagnostic value of spectral reconstructions in detecting incidental skeletal muscle metastases in CT staging examinations

  • Simon Lennartz,
  • Nils Große Hokamp,
  • Nuran Abdullayev,
  • Markus Le Blanc,
  • Andra-Iza Iuga,
  • Grischa Bratke,
  • David Zopfs,
  • David Maintz,
  • Jan Borggrefe,
  • Thorsten Persigehl

DOI
https://doi.org/10.1186/s40644-019-0235-3
Journal volume & issue
Vol. 19, no. 1
pp. 1 – 8

Abstract

Read online

Abstract Background To investigate if iodine density overlay maps (IDO) and virtual monoenergetic images at 40 keV (VMI40keV) acquired from spectral detector computed tomography (SDCT) can improve detection of incidental skeletal muscle metastases in whole-body CT staging examinations compared to conventional images. Methods In total, 40 consecutive cancer patients who underwent clinically-indicated, contrast-enhanced, oncologic staging SDCT were included at this retrospective study: 16 patients with n = 108 skeletal muscle metastases confirmed by prior or follow-up CT, 18F-FDG-PET, MRI or histopathology, and a control group of 24 patients without metastases. Four independent readers performed blinded, randomized visual detection of skeletal muscle metastases in conventional images, IDO and VMI40keV, indicating diagnostic certainty for each lesion on a 5-point Likert scale. Quantitatively, ROI-based measurements of attenuation (HU) in conventional images and VMI40keV and iodine concentration in IDO were conducted. CNR was calculated and receiver operating characteristics (ROC) analysis of quantitative parameters was performed. Results Regarding subjective assessment, IDO (63.2 (58.5–67.8) %) and VMI40keV (54.4 (49.6–59.2) %) showed an increased sensitivity for skeletal muscle metastases compared to conventional images (39.8 (35.2–44.6) %). Specificity was comparable in VMI40keV (69.8 (63.2–75.8) %) and conventional images (69.2 (60.6–76.9) %), while in IDO, it was moderately increased to 74.2 (65.3–78.4) %. Quantitative image analysis revealed that CNR of skeletal muscle metastases to circumjacent muscle was more than doubled in VMI40keV (25.8 ± 11.1) compared to conventional images (10.0 ± 5.3, p ≤ 0.001). Iodine concentration obtained from IDO and HU acquired from VMI40kev (AUC = 0.98 each) were superior to HU attenuation in conventional images (AUC = 0.94) regarding differentiation between healthy and metastatic muscular tissue (p ≤ 0.05). Conclusions IDO and VMI40keV provided by SDCT improve diagnostic accuracy in the assessment of incidental skeletal muscle metastases compared to conventional CT.

Keywords