Development of a Pure Certified Reference Material of D-Mannitol
Weizhu Chen,
Yiping Zhang,
Hui Chen,
Wenhui Jin,
Xiaoying Chen,
Xiaoyan Huang,
Yanrou Xie,
Hua Fang,
Zhuan Hong
Affiliations
Weizhu Chen
Engineering Research Center of Marine Biological Resource Comprehensive Utilization, Third Institute of Oceanography, Ministry of Natural Resource, Xiamen 361005, China
Yiping Zhang
Engineering Research Center of Marine Biological Resource Comprehensive Utilization, Third Institute of Oceanography, Ministry of Natural Resource, Xiamen 361005, China
Hui Chen
Engineering Research Center of Marine Biological Resource Comprehensive Utilization, Third Institute of Oceanography, Ministry of Natural Resource, Xiamen 361005, China
Wenhui Jin
Engineering Research Center of Marine Biological Resource Comprehensive Utilization, Third Institute of Oceanography, Ministry of Natural Resource, Xiamen 361005, China
Xiaoying Chen
Engineering Research Center of Marine Biological Resource Comprehensive Utilization, Third Institute of Oceanography, Ministry of Natural Resource, Xiamen 361005, China
Xiaoyan Huang
Engineering Research Center of Marine Biological Resource Comprehensive Utilization, Third Institute of Oceanography, Ministry of Natural Resource, Xiamen 361005, China
Yanrou Xie
Engineering Research Center of Marine Biological Resource Comprehensive Utilization, Third Institute of Oceanography, Ministry of Natural Resource, Xiamen 361005, China
Hua Fang
Engineering Research Center of Marine Biological Resource Comprehensive Utilization, Third Institute of Oceanography, Ministry of Natural Resource, Xiamen 361005, China
Zhuan Hong
Engineering Research Center of Marine Biological Resource Comprehensive Utilization, Third Institute of Oceanography, Ministry of Natural Resource, Xiamen 361005, China
A new certified reference material (CRM) of D-mannitol (GBW(E) 100681) has been developed in this study. We describe the preparation, structure determination, characterization, homogeneity study, stability study, as well as uncertainty estimation. The main component was 99.91% ± 0.01%. The moisture content of the candidate CRM was 0.036% ± 0.002%, as measured by Karl Fischer titration. The nonvolatile and volatile impurities in the candidate CRM were all much less than 0.01%, which was determined by the ICP–MS and headspace GC–FID methods, respectively. The purity of the D-mannitol CRM was 99.9% ± 1.1% (k = 2), as measured by the two independent approaches involving the mass balance method (MB) and quantitative nuclear magnetic resonance technique (qNMR). The D-mannitol CRM was stable during the monitoring period for each temperature. It is stable for up to 48 months at room temperature and 28 days at 50 °C. The uncertainty was evaluated by combining the contributions from characterization, homogeneity, and stability. The developed D-mannitol CRM would effectively support method validation and proficiency testing, as well as effectively guarantee the accuracy, reliability, and comparability of results.