Xiehe Yixue Zazhi (May 2024)

Accuracy of Contrast-Enhanced Ultrasound Diagnostic Reports for 859 Cases of Pancreatic Space-occupying Lesions

  • GUI Yang,
  • LYU Ke,
  • LIANG Hua,
  • CHEN Xueqi,
  • JIA Wanying,
  • CHEN Tianjiao,
  • JIANG Yuxin

DOI
https://doi.org/10.12290/xhyxzz.2024-0204
Journal volume & issue
Vol. 15, no. 4
pp. 825 – 830

Abstract

Read online

ObjectiveTo evaluate the accuracy of contrast-enhanced ultrasound diagnostic reports for pancreatic lesions.MethodsIn this retrospective study, we included patients who underwent contrast-enhanced ultrasound examination of pancreatic lesions at Peking Union Medical College Hospital from January 2017 to December 2022 and received a confirmed pathological diagnosis. Using pathological diagnosis as the gold standard, the study evaluated the accuracy of contrast-enhanced diagnostic ultrasound. It also analyzed the misdiagnosis of contrast-enhanced ultrasound in diagnosing various pathological types of pancreatic lesions.ResultsOf the 859 patients who met inclusion and exclusion criteria, 489 were male(56.9%) and 370 were female(43.1%).Their age ranged from 16 to 85 years, with a median age of 60(53, 66) years. Except for 47 pancreatic space-occupying lesions that were difficult to categorize as either benign or malignant, a total of 812 cases were included in the diagnostic efficacy analysis of benign and malignant lesions. The results suggested that the diagnostic sensitivity and specificity of contrast-enhanced ultrasound for pancreatic malignant lesions were 98.3%(95% CI: 97.1%-99.1%) and 79.0%(95% CI: 70.1%-86.4%), AUC was 0.887(95% CI: 0.863-0.908), positive and negative predictive value were 96.9%(95% CI: 95.6%-97.9%) and 87.4%(95% CI: 79.6%-92.4%), positive and negative likelihood ratio were 4.69(95% CI: 3.24-6.80) and 0.02(95% CI: 0.01-0.04). The diagnostic accuracy rate of contrast-enhanced ultrasound for diagnosing benign and malignant pancreatic lesions was 95.8%. Of the 859 lesions examined, 48 cases were misdiagnosed by contrast-enhanced ultrasound, with a misdiagnosis rate of 5.6%(48/859), including 7 cases(0.8%) of undetermined diagnosis, while the diagnostic accuracy of pancreatic ductal adenocarcinoma was as high as 98.8%. No complications occurred in any of the patients.ConclusionsContrast-enhanced ultrasound is a safe and effective imaging method for evaluating microvascular perfusion in various pancreatic lesions. It has significant clinical value in diagnosing both benign and malignant pancreatic lesions, particularly in diagnosing pancreatic ductal adenocarcinoma.

Keywords