Journal of Clinical Medicine (Oct 2022)

Temporal Change in Anterior Chamber Depth after Combined Vitrectomy and Cataract Surgery Using Different Sizes of Intraocular Lens

  • Yoshiaki Takahashi,
  • Takao Hirano,
  • Marie Nakamura,
  • Yoshiaki Chiku,
  • Ken Hoshiyama,
  • Satoko Akahane,
  • Keita Akahane,
  • Toshinori Murata

DOI
https://doi.org/10.3390/jcm11216430
Journal volume & issue
Vol. 11, no. 21
p. 6430

Abstract

Read online

This study aimed to investigate the temporal changes in the anterior chamber depth (ACD) and refractive prediction error (RPE) of 6 and 7 mm diameter intraocular lenses (IOLs) after cataract surgery or phacovitrectomy with or without sulfur hexafluoride (SF6) gas. We reviewed 120 eyes (120 patients) and divided them into six groups: three groups of cataract surgery alone and phacovitrectomy (with or without SF6), which were further divided according to IOL diameter (6 and 7 mm) used. We examined the ACD and IOL position using a swept-source anterior segment optical coherence tomograph at 1 day, 1 week, and 1 month postoperatively; and the RPE at 1 month postoperatively. The ACD and IOL position at postoperative day 1 in the SF6 injection groups were significantly smaller than those in the other groups (p p < 0.01); thus, complications such as synechia or pupillary capture should be considered in the early postopera-tive period of phacovitrectomy with SF6, especially in the 6 mm IOL. The ACD, IOL position, and RPE at 1 month did not significantly differ among the groups, regardless of the IOL diameter or SF6. In the SF6 injection groups, the ACD and IOL position gradually deepened with less gas.

Keywords