Energies (Apr 2022)

Emission Characteristics of Polychlorinated Dibenzo-p-Dioxins/Dibenzofurans (PCDD/DFs) in Commercial Bio-SRF and SRF Incineration Plants

  • Jun-Ik Son,
  • Seung-Jae Lee,
  • Se-In Park,
  • Eun-Hye Kwon,
  • Hueon Namkung,
  • Jun-Gu Kang,
  • Wonseok Lee

DOI
https://doi.org/10.3390/en15082787
Journal volume & issue
Vol. 15, no. 8
p. 2787

Abstract

Read online

Incineration plants using solid refused fuel (SRF) should control their air pollution materials to minimize environmental impact. This study evaluated the emission of polychlorinated dibenzo-p-dioxin/dibenzofurans (PCDD/DFs) congener patterns in seven commercial incineration plants in Korea using SRF and biomass SRF (bio-SRF). We examined the reduction rate differences of PCDD/DFs, depending on the air pollutant control device. All seven incineration plants sufficiently managed their dioxin emissions. However, both SRF and bio-SRF incineration plants showed active chlorination reactions and resulted in a large amount of highly chlorinated dioxins. The average dioxin concentration was 0.02 ng international toxic equivalency quantity (I-TEQ)/Sm3. Ratios of 1,2,3,4,6,7,8-HpCDF and 1,2,3,7,8-PeCDF were high in the waste heat boilers of both SRF and bio-SRF incineration plants. The octachlorinated dibenzofuran (OCDF) ratio was only high in the SRF incineration plants. Octachlorodibenzo-p-dioxin (OCDD) and OCDF exhibited high dioxin ratios. SRF incineration plants had a low ratio of OCDF to 1,2,3,4,6,7,8-HpCDF. In addition, the reduction rate of PCDD/DFs was substantially high after treatment with the air pollutant control device.

Keywords