A Study on Temperature and Pressure Characteristics in a Vessel as Charging Time of Helium Gas Changes
Abstract
The main propose in this research work is to investigate the temperature and pressure increase resulting from the variable valve of a mass flow controller during the charging and discharging of helium gas, which is being used as an alternative to hydrogen gas in a vessel. In the operation of this experiment, the high-pressure gas stored in the main tank is first reduced to low pressure using an electronic solenoid valve within a regulator to control the flow rate. Subsequently, the flow rate is precisely measured using an MFC (Mass Flow Controller) and supplied to the experimental tank. Throughout this process, temperature and pressure sensors detect changes in physical behavior, collect data using LabVIEW cDAQ, and repeat the process of analyzing and verifying reliable data according to the experiment’s conditions. The mass flow controller valve opening was set at 20%, 60%, and 100% while operating the LabVIEW programming. Also, this experiment was conducted at 20 °C ambient temperature and 0 bar gauge pressure. Both the temperature and pressure increase as the MFC valve opens further because the helium gas flow is accumulating during the valve opening time. Furthermore, in the case of helium temperature, it increases significantly when the gas is charged rapidly, compared to the pressure characteristics. Therefore, one can see that the vessel increases as the valve opening time increases, and the temperature changes; the temperature is more significant when the helium gas is charged rapidly during the valve opening time.