JSES Reviews, Reports, and Techniques (Feb 2021)

Treatment of olecranon fractures using an intramedullary cancellous screw and suture tension band: minimum 2-year follow-up

  • Julio J. Contreras Fernández, MD,
  • Manuel Beltrán, MD,
  • Carlos Córdova, MD,
  • Sergio Benavente, MD,
  • Cristóbal Díaz, MD,
  • Nicolás Rojas, MD,
  • Sebastián Vial, MD,
  • Alonso Díaz, MD,
  • Eduardo Otero, MD,
  • Héctor Palomo, MD,
  • Rodrigo Liendo, MD,
  • Francisco Soza, MD

Journal volume & issue
Vol. 1, no. 1
pp. 26 – 33

Abstract

Read online

Background: Tension band wiring and plates are the most widely used treatments for transverse displaced fractures of olecranon despite high rates of hardware complications, subsequent implant removal, and associated costs. The purpose of this study was to report the outcomes of displaced transverse olecranon fractures treated with intramedullary screw and suture tension band. Methods: We performed an observational, retrospective, consecutive, monocentric, continuous multioperator study. We reviewed 31 Mayo type IIA displaced olecranon fractures treated in our institution with intramedullary 6.5 mm AO cancellous screw and high-strength suture tension band (No. 2 FiberWire®) from 2016 to 2018. Inclusion was limited to functionally independent patients with Mayo type IIA fractures and minimum 24-month follow-up for implant removal. We assessed clinical outcomes including range of motion; QuickDASH score; and Mayo Elbow Performance Score. Categorical data were analyzed with Fisher's exact test when appropriate. Continuous data were analyzed with the Student t-test or Mann-Whitney U test after assessment for normality. Statistical analysis was performed with STATA 16 software. Results: Twenty-seven patients with a mean follow-up period of 38.4 ± 6.2 months (range, 24.1-50 months) were included in the study. The average flexion was 134.5° ± 14.8° (range, 70°-140°) and the mean extension was −5.9° ± 7.0° (range, −20°-0°). Mean pronation and supination were 85.8° ± 11.9° (range, 45°-90°) and 86.9° ± 14.3° (range, 20°-90°), respectively. The mean Mayo Elbow Performance Score was 90.8 ± 9.6 (range, 70-100) with 92.3% good and excellent results. The mean QuickDASH score was 17.1 ± 16 (range, 0-54.5). There were 3 hardware-related removals (11.1%). The overall removal rate was 18.5%. Univariate analysis of the factors associated with implant removal were pain in relation to the implant (60% vs. 11%, P = 0.0482), proximal screw migration (3.7 mm vs. 1.7 mm, P = 0.05), articular angle (22.5° vs. 27.7°, P = 0.0353), and olecranon width (22.2 mm vs. 24.4 mm, P = 0.0166). In total, 26.1% of the cases presented some degree of proximal migration of the implant (2.7 ± 1.8 mm of migration; range, 1.5-6.2 mm). Univariate analysis of the factors associated with implant proximal migration were proximal ulnar dorsal angulation (1.7° vs. 6.4°, P = 0.0179), anteroposterior endomedullary canal (7.3 mm vs. 6.0 mm, P = 0.0369), and lateral endomedullary canal (7.2 mm vs. 5.0 mm, P = 0.0219). Conclusion: The functional outcomes of simple transverse olecranon fractures treated with an intramedullary cancellous screw and a suture tension band are excellent, associated with a low rate of complications and material removal.

Keywords