Análise do nível de ruído em unidade de terapia intensiva adulto

  • Helen Katharine Christofel,
  • Joselene Gomes Madeiras,
  • Sônia Maria Marques Gomes Bertolini,
  • Juliana Maria de Oliveira

Journal volume & issue
Vol. 17, no. 4
pp. 553 – 560

Abstract

Read online

Objective: to analyze the noise level in adult intensive care unit. Methods: a quantitative study, in which the sound levels of the intensive care unit have been assessed by means of a decibel meter. Results: comparing the groups, there was a reduction in noise levels in both periods studied, but only in the afternoon there was a statistically significant difference (p<0.05). The health professionals pointed out that the unit had moderate noise, coming mainly from equipment and professionals. Conclusion: adjusting the ventilator alarms contributed to the reduction of noise levels in the unit, and there was the perception that it is a moderate noise environment, although the noise levels in decibels observed were above the recommended values.