Impacts of Varying Blood Flow Restriction Cuff Size and Material on Arterial, Venous and Calf Muscle Pump-Mediated Blood Flow
Steven B. Machek,
Dillon R. Harris,
Jeffery L. Heileson,
Dylan T. Wilburn,
Jeffrey S. Forsse,
Darryn S. Willoughby
Affiliations
Steven B. Machek
Integrated Laboratory of Exercise, Nutrition, and Renal Vascular Research, Department of Health, Human Performance, and Recreation, Robbins College of Health and Human Sciences, Baylor University, Waco, TX 76706, USA
Dillon R. Harris
Integrated Laboratory of Exercise, Nutrition, and Renal Vascular Research, Department of Health, Human Performance, and Recreation, Robbins College of Health and Human Sciences, Baylor University, Waco, TX 76706, USA
Jeffery L. Heileson
Integrated Laboratory of Exercise, Nutrition, and Renal Vascular Research, Department of Health, Human Performance, and Recreation, Robbins College of Health and Human Sciences, Baylor University, Waco, TX 76706, USA
Dylan T. Wilburn
Integrated Laboratory of Exercise, Nutrition, and Renal Vascular Research, Department of Health, Human Performance, and Recreation, Robbins College of Health and Human Sciences, Baylor University, Waco, TX 76706, USA
Jeffrey S. Forsse
Integrated Laboratory of Exercise, Nutrition, and Renal Vascular Research, Department of Health, Human Performance, and Recreation, Robbins College of Health and Human Sciences, Baylor University, Waco, TX 76706, USA
Darryn S. Willoughby
Integrated Laboratory of Exercise, Nutrition, and Renal Vascular Research, Department of Health, Human Performance, and Recreation, Robbins College of Health and Human Sciences, Baylor University, Waco, TX 76706, USA
Blood flow restriction (BFR) may become ineffective or potentially dangerous without sufficient standardization. The purpose of this investigation was therefore to (1) assess the viability of multiple sizes of a novel BFR cuff to determine arterial occlusion pressure (AOP) and (2) compare resting arterial, venous and calf muscle pump (cMP)-mediated blood flow between the aforementioned conditions and a commonly employed wide-rigid, tourniquet-style cuff. In randomized, counter-balanced, and crossover fashion, 20 apparently healthy males (18–40 years) donned a widely employed wide-rigid (WR) cuff, along with the largest (NE) and manufacturer-recommended sizes (NER) of a novel narrow-elastic cuff. Participants subsequently assessed AOP, as well as (at 80%AOP) arterial, venous, and venous cMP flow relative to baseline values via ultrasound. All analyses were performed at a significance level of p p p2 = 0.907) whereby WR was significantly lower than both NE and NER; in addition, the latter two did not differ. Compared with baseline, there were no statistically significant differences between cuffs for either arterial or cMP-mediated blood flow. Unsurprisingly, no participants demonstrated venous blood flow at 80% AOP. These findings support the viability of a novel narrow-elastic BFR product, evidenced by consistent AOP acquisition and equivocal blood flow parameters.