Acta Veterinaria (Mar 2022)
Development and Validation of an Improved HPLC-UV Method for the Determination of Tildipirosin in Horse Plasma
Abstract
A simple, rapid, low-cost, and sensitive high-performance liquid chromatographic method was developed to determine tildipirosin in horse plasma. Plasma samples were extracted with diethyl ether, and after evaporation, tildipirosin was determined by reverse-phase chromatography with an ultraviolet detector set at a wavelength of 289 nm. Tildipirosin was separated on a Zorbax Eclipse XDB-C18 column, 150 x 3.0 mm, 5 μm with gradient chromatographic elution. The retention times were 3.0 min and 6.4 min for tildipirosin and tylosin tartrate, respectively. The total run time was 9 minutes in this method.