Journal of Dental Research, Dental Clinics, Dental Prospects (Dec 2018)
Apically extruded debris and irrigants during root canal filling material removal using Reciproc Blue, WaveOne Gold, R-Endo and ProTaper Next systems
Abstract
Background. The present study aimed to compare the amount of apically extruded debris and irrigants produced by various nickel-titanium instruments. Methods. A total of 100 single-rooted mandibular premolar teeth were root canal treated and prepared for agar gel model. The root canal fillings were removed using Reciproc Blue, ProTaper Next, R-Endo, WaveOne Gold systems or hand instrumentation. The mean weights of apically extruded materials were calculated. Data were statistically analyzed using one-way ANOVA and post hoc Bonferroni tests. Results. Hand instrumentation resulted in significantly more debris and irrigants than other systems (P0.05), while they both produced significantly less apically extruded material than R-Endo system (P<0.05). Conclusion. All the instruments caused apical extrusion. ProTaper Next and WaveOne Gold systems were associated with significantly less apical extrusion.