Nuclear Engineering and Technology (Apr 2023)

Beam position measurement system at HIRFL-CSRm

  • Min Li,
  • Guoqing Xiao,
  • Ruishi Mao,
  • Tiecheng Zhao,
  • Youjin Yuan,
  • Weilong Li,
  • Kai Zhou,
  • Xincai Kang,
  • Peng Li,
  • Juan Li

Journal volume & issue
Vol. 55, no. 4
pp. 1332 – 1341

Abstract

Read online

Beam position measurement system can not only provide the beam position monitoring, but also be used for global orbit correction to reduce beam loss risk and maximize acceptance. The Beam Position Monitors (BPM) are installed along the synchrotron to acquire beam position with the front-end electronics and data acquisition system (DAQ). To realize high precision orbit measurement in the main heavy ion synchrotron and cooling storage ring of heavy-ion research facility in Lanzhou (HIRFL-CSRm), a series of alignment and calibration work has been implemented on the BPM and its DAQ system. This paper analyzed the tests performed in the laboratory as well as with beam based on the developed algorithms and hardware. Several filtering algorithms were designed and implemented on the acquired BPM raw data, then the beam position and resolution were calculated and analyzed. The results show that the position precision was significantly improved from more than 100 μm to about 50 μm by implementing the new designed filtering algorithm. According to the analyzation of the measurement results and upcoming physical requirements, further upgrade scheme for the BPM DAQ system of CSRm based on field programmable gate array (FPGA) technology was proposed and discussed.

Keywords