Revista Brasileira de Ortopedia (Jan 2010)

Fraturas da extremidade distal da tíbia tratadas pela haste intramedular e placa em ponte: comparação do tempo de exposição à radiação nos dois métodos Fractures of distal third extremity of the tibia treated with intramedullary nail and bridge plate: comparison of radiation exposure time in the two methods

  • Pedro José Labronici,
  • Fábio Soares Lyra,
  • Ildeu Leite Moreira Junior,
  • Rolix Hoffmann,
  • José Sergio Franco,
  • Paulo Roberto Barbosa de Toledo Lourenço,
  • Gustavo José Labronici

DOI
https://doi.org/10.1590/S0102-36162010000200004
Journal volume & issue
Vol. 45, no. 2
pp. 132 – 135

Abstract

Read online

OBJETIVO: Comparar o tempo de exposição à radiação nos pacientes com fratura do terço distal da tíbia tratados com haste intramedular e placa em ponte. MÉTODOS: Em 33 fraturas foram utilizadas hastes intramedulares e em 41, placas em ponte. No grupo haste, segundo a classificação AO, 14 pacientes apresentavam fraturas do tipo A, 15 do tipo B e quatro, do tipo C. Doze pacientes sofreram fraturas fechadas e 21, expostas. No grupo placa, 10 pacientes apresentavam fraturas do tipo A, 22 do tipo B e nove do tipo C. Vinte e sete pacientes sofreram fraturas fechadas e 14 expostas. RESULTADOS: Observou-se que existe diferença significativa no tempo de exposição à radiação entre pacientes tratados com haste e placa (p = 0,0001). O grupo tratado com haste apresentou tempo de exposição à radiação significativamente maior que o grupo com placa. Quando comparado o tipo de fratura (A, B e C), observou-se que não existe diferença significativa no tempo de exposição à radiação quando utilizada a técnica de haste (p = 0,19) e placa (p = 0,80). CONCLUSÃO: Fraturas do terço distal da tíbia tratadas com haste intramedular apresentam um tempo de exposição à radiação significativamente maior do que as fraturas tratadas com placa em ponte, independente do tipo de fratura.OBJECTIVE: To compare the exposure time to radiation in patients with distal third fractures of the tibia treated with intramedullary nail and bridge plate. METHODS: In 33 fractures intramedullary nails were used, and in 41 fractures plates were used. In the intramedullary nail group, according to the AO classification, 14 patients had type A fractures, 15 patients had type B fractures and four had type C fractures. Twelve patients had closed fractures and 21 had open fractures. In the plate group, 10 patients had type A fractures, 22 patients had type B fractures and nine had type C fractures. 27 patients had closed fractures and 14 had open fractures. RESULTS: A significant difference was observed in exposure time to radiation between the patients treated with the intramedullary nail and the plate (p = 0.0001). The group treated with the intramedullary nail had a significantly higher exposure time to the radiation than the group treated with the plate. Comparing the type of fracture (A, B and C), it was observed that there is no considerable difference in exposure time to radiation between the intramedullary nail technique (p = 0.19) and the plate technique (p = 0.80). CONCLUSION: Fractures of distal third of the tibia treated with intramedullary nail show considerably higher exposure time to radiation than fractures treated with the bridge plate, independent of fracture type.

Keywords