Diagnostics (Feb 2024)

Long-Term Comparison of Two- and Three-Dimensional Computed Tomography Analyses of Cranial Bone Defects in Severe Parietal Thinning

  • Johannes Dominikus Pallua,
  • Anton Kasper Pallua,
  • Werner Streif,
  • Harald Spiegl,
  • Clemens Halder,
  • Rohit Arora,
  • Michael Schirmer

DOI
https://doi.org/10.3390/diagnostics14040446
Journal volume & issue
Vol. 14, no. 4
p. 446

Abstract

Read online

Parietal thinning was detected in a 72-year-old with recurrent headaches. Quantification of bone loss was performed applying two- and three-dimensional methods using computerized tomographies. Two-dimensional methods provided accurate measurements using single-line analyses of bone thicknesses (2.13 to 1.65 and 1.86 mm on the left and 4.44 to 3.08 and 4.20 mm on the right side), single-point analyses of bone intensities (693 to 375 and 403 on the left and 513 to 393 and 411 Houndsfield Units on the right side) and particle-size analyses of low density areas (16 to 22 and 12 on the left and 18 to 23 and 14 on the right side). Deteriorations between days 0 and 220 followed by bone stability on day 275 were paralleled using the changed volumes of bone defects to 1200 and finally 1133 mm3 on the left side and to 331 and finally 331 mm3 on the right side. Interfolding as measurement of the bones’ shape provided changes to −1.23 and −1.72 mm on the left and to −1.42 and −1.30 mm on the right side. These techniques suggest a stabilizing effect of corticosteroids between days 220 and 275. Reconstruction of computerized tomographies appears justified to allow for quantification of bone loss during long-term follow-up.