Química Nova (Jan 2010)

Determination of 5-aminosalicylic acid in pharmaceutical formulations by square wave voltammetry at pencil graphite electrodes

  • Carolina V. Uliana,
  • Hideko Yamanaka,
  • Gustavo S. Garbellini,
  • Giancarlo R. Salazar-Banda

DOI
https://doi.org/10.1590/S0100-40422010000400036
Journal volume & issue
Vol. 33, no. 4
pp. 964 – 967

Abstract

Read online

An analytical method for the determination of the anti-inflammatory drug 5-aminosalicylic acid (5-ASA) in pharmaceutical formulations using square wave voltammetry at pencil graphite electrodes was developed. After the optimization of the experimental conditions, calibration curves were obtained in the linear concentration range from 9.78 × 10-7 to 7.25 × 10-5 mol L-1 resulting in a limit of detection of 2.12 ± 0.05 x 10-8 mol L-1. Statistical tests showed that the concentrations of 5-ASA in commercial tablets and enemas obtained with the proposed voltammetric method agreed with HPLC values at a 95% confidence level.

Keywords