Brazilian Journal of Cardiovascular Surgery (Jun 2007)

Avaliação ecocardiográfica em pacientes submetidos à substituição de cordas tendíneas rotas Echocardiographic evaluation of patients submitted to replacement of ruptured chordae tendineae

  • João Carlos Leal,
  • Francisco Gregori Jr,
  • Luis Eduardo Galina,
  • Rubens S. Thevenard,
  • Domingo Marcolino Braile

DOI
https://doi.org/10.1590/S0102-76382007000200006
Journal volume & issue
Vol. 22, no. 2
pp. 184 – 191

Abstract

Read online

OBJETIVO: O objetivo deste estudo é avaliar, ao ecodopplercardiograma (ECO), o funcionamento do aparelho valvar mitral, em pacientes submetidos ao implante de cordas padronizadas de pericárdio bovino (CP de PB) para substituição de cordas tendíneas rotas ou alongadas com grau importante de afilamento. MÉTODO: Foram implantadas CP de PB em 23 pacientes portadores de insuficiência mitral por ruptura das cordas tendíneas ou cordas alongadas com afilamento importante. A idade variou de 23 a 85 anos (média de 62 anos). A causa mais freqüente foi a degeneração fibroelástica em 20 (87,0%) pacientes. As CP de PB foram confeccionadas em conjunto, unidas em suas extremidades por duas hastes reforçadas com poliéster formando um monobloco. As CP de PB medem dois mm de largura e distam entre si, paralelamente, por três mm. Cada conjunto CP de PB possui um medidor correspondente, variando seu comprimento entre 20 a 35 mm. Em 17 (73,9%) pacientes foram implantadas as CP de PB na cúspide posterior e, em seis (26,1%), na cúspide anterior. Todos os pacientes foram avaliados no pós-operatório pelo ECO, com tempo médio de seguimento de até seis meses. RESULTADOS: O ECO no pós-operatório demonstrou ausência de refluxo em 11 (47,8%) pacientes, refluxo discreto em oito (34,8%) e refluxo discreto/moderado em três (13,0%). A abertura e mobilidade da valva mitral eram normais nos 22 pacientes sobreviventes. CONCLUSÃO: O ECO demonstrou boa funcionalidade do aparelho valvar mitral nos pacientes submetidos ao implante das CP de PB para substituição de cordas tendíneas rotas ou alongadas e afiladas com adequada coaptação das cúspides.OBJECTIVE: The objective of this study was to evaluate, using echocardiography, the functioning of the mitral valve apparatus in patients submitted to standardized bovine pericardium chordae implantation to substitute ruptured chordae tendineae or elongated chordae with a significant degree of thinning. METHOD: Standardized bovine pericardium chordae were implanted in 23 patients with mitral valve insufficiency due to ruptured or elongated chordae with significant thinning. The ages of the patients varied from 23 to 84 years old (mean 62 years old). The most common cause was fibroelastic degeneration affecting 20 (87.0%) patients. The standardized bovine pericardium chordae were manufactured in sets connected at both ends by two polyester-reinforced rods thereby forming a single block. The bovine pericardium chordae measure 2 mm wide with 3 mm between the chordae. The sets of bovine pericardium chordae are produced in lengths varying from 20 to 35 mm. In 17 (73.9%) patients bovine pericardium chordae were implanted in the posterior cusp and in 6 (26.1%) in the anterior cusp. All the patients were evaluated in the postoperative period by echocardiography after a mean follow-up of six months. RESULTS: The echocardiography in the postoperative period demonstrated an absence of reflux in 11 (47.8%) patients, slight reflux in 8 (34.8%) and slight to moderate reflux in 3 (13.0%). The opening and mobility of the mitral valve was normal in the 22 surviving patients. CONCLUSION: The echocardiography demonstrated good functioning of the mitral valve apparatus in patients submitted to the implantation of standardized bovine pericardium chordae to substitute ruptured chordae tendineae or elongated chordae with a significant degree of thinning.

Keywords