Hydroxyapatite Affects the Physicochemical Properties of Contemporary One-Step Self-Etch Adhesives
Yutaro Motoyama,
Monica Yamauti,
Masatoshi Nakajima,
Masaomi Ikeda,
Junji Tagami,
Yasushi Shimada,
Keiichi Hosaka
Affiliations
Yutaro Motoyama
Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8510, Japan
Monica Yamauti
Department of Restorative Dentistry, Graduate School of Dental Medicine, Hokkaido University, Kita 13 Nishi 7, Sapporo 060-8586, Japan
Masatoshi Nakajima
Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8510, Japan
Masaomi Ikeda
Oral Prosthetic Engineering, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8510, Japan
Junji Tagami
Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8510, Japan
Yasushi Shimada
Department of Cariology and Operative Dentistry, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo 113-8510, Japan
Keiichi Hosaka
Department of Regenerative Dental Medicine, Graduate School of Medical and Dental Sciences, Tokushima University, 3-18-15 Kuramoto-Cho, Tokushima 770-8504, Japan
The study aimed to evaluate the influence of the manipulation surfaces on the physical properties of one-step self-etch adhesives (1-SEAs). Scotchbond Universal (SBU), Clearfil Universal Bond Quick ER (UBQ), and an experimental adhesive (UBQexp) were manipulated on different surfaces: manufacturer’s Teflon-based dispensing dish (TD) or hydroxyapatite plate (HA). After manipulation of the adhesives, the pH of each 1-SEA was measured. Samples of each adhesive/manipulation surface were prepared and subjected to water sorption (WS)/solubility (SL) and flexural strength tests. The modulus of elasticity (E) was measured in dry and wet conditions before and after 24 h water storage, and the percentage of variation of E (ΔE) was calculated. Results were analyzed using the t-test with Bonferroni corrections (α = 0.05). When adhesives were manipulated on the HA plate, there was a significant increase in the adhesives’ pH. WS and SL of all 1-SEAs decreased when the HA was used. Only SBU showed higher flexural strength when manipulated on the HA compared to the manipulation on TD under dry and wet conditions. For each 1-SEA, the use of HA resulted in significantly higher E in dry and wet conditions. ΔE of all adhesives was smaller with the manipulation on HA than on TD. It was concluded that the manipulation of 1-SEA on a hydroxyapatite plate considerably affected the adhesives’ properties.