PLoS ONE (Jan 2023)

Effect of optional biometric parameters in the Kane formula on intraocular lens power calculation.

  • Xiao-Yu Li,
  • Xuan Liao,
  • Jia Lin,
  • Chang-Jun Lan,
  • Qing-Qing Tan

DOI
https://doi.org/10.1371/journal.pone.0289033
Journal volume & issue
Vol. 18, no. 8
p. e0289033

Abstract

Read online

PurposeTo investigate the effect of the optional biometric parameters lens thickness (LT) and center corneal thickness (CCT) in the Kane formula on intraocular lens (IOL) power calculation.MethodsA cross-sectional study included consecutive cataract patients who received uncomplicated cataract surgery with IOL implantation from May to September 2022 were enrolled. The ocular biometric parameters were obtained using IOLMaster 700 and then inputted into online Kane formula calculator. The IOL power was calculated for targeting emmetropia and compared between groups: not omitting (NO) group, omitting LT and CCT (OLC) group, omitting LT (OL) group and omitting CCT (OC) group. Further, according to the axial length (AL), anterior chamber depth (ACD), and mean keratometry (Km), the eyes were divided into three subgroups, respectively.Results1005 eyes of 1005 consecutive patients were included. There was no significant difference in IOL power between NO group and OC group (P = 0.064), and the median absolute difference (MedAD) was 0.05D. The IOL power in NO group showed significant differences from OLC group and OL group respectively (P ConclusionThe optional biometric parameter CCT has no effect on the calculation results of the Kane formula, whereas the parameter LT has a great influence on the Kane formula results for the IOL power calculation in cataract patients with short AL, shallow ACD and steep Km.