Energies (Nov 2021)

Modelling Ground Collectors and Determination of the Influence of Technical Parameters, Installation and Geometry on the Soil

  • Ľubomíra Gabániová,
  • Dušan Kudelas,
  • Martin Prčík

DOI
https://doi.org/10.3390/en14217153
Journal volume & issue
Vol. 14, no. 21
p. 7153

Abstract

Read online

The main objective of this work was to model ground collectors with different parameters and geometries in ANSYS R19.2 and to simulate their operation during the heating season in Slovakia in order to determine their impact on the soil. At the same time, four new geometries in the shape of vertical spirals with diameters of 6, 8 and 10 m were designed and simulated to occupy a smaller area while maintaining performance similar to classical geometries. Due to climate change, heat pumps are becoming an important proxy in the heating of buildings and are an important part of decarbonisation plans; thus, it is essential to adapt them to urban and metropolitan conditions. Ground source heat pumps possess high efficiency but require a lot of space for their collectors. The collector geometries proposed in this work are a combination of horizontal and vertical technologies and are feasible. Only one geometry achieved performance similar to classical geometries: spiral with 10 m diameter. Factors significantly influencing collector operation were confirmed, namely season, soil type, soil water content, geometry and collector placement.

Keywords