Journal of Medical Radiation Sciences (Mar 2024)

A comparison of bolus track and test bolus computed tomography pulmonary angiography and the implications on pulmonary and aortic vessel enhancement, effective dose and suboptimal scan rate

  • Aoife Murphy,
  • Helen White

DOI
https://doi.org/10.1002/jmrs.724
Journal volume & issue
Vol. 71, no. 1
pp. 44 – 50

Abstract

Read online

Abstract Introduction Bolus track and test bolus are the most commonly used contrast timing protocols to undertake computed tomography pulmonary angiography (CTPA). The aim of this study was to compare test bolus and bolus track contrast enhancement protocols in terms of enhancement of the pulmonary vessels and aorta, radiation dose and suboptimal scan rate to determine the optimal technique for CTPA. Methods A total of 200 CTPA examinations (100 using each protocol) performed between January and February 2021 were assessed retrospectively. All scans were performed on a 2x128 Dual Source Siemens Drive Scanner. CT attenuation was measured in Hounsfield Units (HU), with measurements taken from the main pulmonary trunk, right pulmonary artery and left pulmonary artery, ascending and descending aorta. The mean effective dose was calculated from the dose‐length product (DLP). The suboptimal scan rate was calculated as the percentage of examinations below 210HU. Results The average HU of the pulmonary arteries was 358 HU ± SD 129.2 in the test bolus group and increased to 394 HU ± SD 133.9 in the bolus track group with a P value of ≤0.05. The average HU of the aorta was 235 HU ± SD 82.8 in the test bolus group and increased to 319 HU ± SD 91.8 in the bolus track group with a P value of 0.05). Fewer suboptimal scans were performed with the bolus track protocol (5 scans <210HU Bolus Track vs. 9 scans <210HU Test Bolus). Conclusion The bolus track protocol results in increased enhancement of the pulmonary arteries and aorta, with the added benefits of a lower suboptimal scan rate and lower effective dose.

Keywords