BMC Research Notes (Jan 2022)

Comparison of insertion time, pull-out strength, and screw-media interface area of customized pedicle screw with different core and thread design against commercial pedicle screw: a pilot study on Indonesian Population

  • Rahadyan Magetsari,
  • Tedjo Rukmoyo,
  • Marda Ade Saputra,
  • Yudha Mathan Sakti

DOI
https://doi.org/10.1186/s13104-021-05803-5
Journal volume & issue
Vol. 15, no. 1
pp. 1 – 5

Abstract

Read online

Abstract Objective This research aimed to developing customized pedicle screw based on Indonesian vertebral anatomy and compare the insertion time, pull-out strength, and screw-media interface area of different screw design. We have developed 3 different types of pedicle screws (v-thread cylinder-core, square-thread cylinder-core and square-thread conical-core). The thread diameter was calculated from pedicle width of Indonesian population (6 mm). We used commercially available pedicle screw as control group (6.2 mm). Result The insertion time were significantly difference between v-thread cylinder-core pedicle screw (22.94 s) with commercially available pedicle screw (15.86 s) (p < 0.05). The pull-out strength was significantly difference between commercially available pedicle screw (408.60 N) with square-thread conical pedicle screw (836.60 N) (p < 0.05). The square-thread conical-core group have the highest interface area (1486.21 mm2). The data comparison showed that the square-thread conical-core customized pedicle screw group has comparable insertion time and has better pull-out strength than commercially available pedicle screw.

Keywords