Polymers (Jan 2022)

Adhesive-Free Adhesion between Plasma-Treated Glass-Cloth-Containing Polytetrafluoroethylene (GC–PTFE) and Stainless Steel: Comparison between GC–PTFE and Pure PTFE

  • Misa Nishino,
  • Yuki Okazaki,
  • Yosuke Seto,
  • Tsuyoshi Uehara,
  • Katsuyoshi Endo,
  • Kazuya Yamamura,
  • Yuji Ohkubo

DOI
https://doi.org/10.3390/polym14030394
Journal volume & issue
Vol. 14, no. 3
p. 394

Abstract

Read online

In this study, the effect of plasma treatment on glass-cloth-containing polytetrafluoroethylene (GC–PTFE) was investigated. Previous plasma studies investigated pure PTFE (which does not contain glass cloth) but not GC–PTFE. The effect of Ar + H2O plasma treatment on GC–PTFE was investigated. The Ar + H2O plasma-treated GC–PTFE sheets were thermally compressed to stainless steel (SUS304) foils without using adhesive, and the GC–PTFE/SUS304 adhesion strengths were measured using a 90° peel test. The adhesion strength increased with the increase in the plasma treatment time (0.8 and 1.0 N/mm at 20 s and 300 s, respectively). Thus, strong adhesion between GC–PTFE/SUS304 was achieved without adhesive. This improvement in the adhesion properties of GC–PTFE can be attributed to the generation of oxygen-containing functional groups and the decrease in the surface roughness of the samples. Thereafter, the adhesion properties of GC–PTFE and pure PTFE were compared. Because, unlike pure PTFE, GC–PTFE has no weak boundary layer, GC–PTFE exhibited better adhesion properties than pure PTFE under short plasma treatment times.

Keywords