Perm Journal of Petroleum and Mining Engineering (Sep 2017)

Results of modelling of mine ventilation with air curtain installed into downcast and upcast shafts

  • Aleksandr V. Nikolaev,
  • Nikolay I. Alymenko,
  • Anton A. Kamenskikh,
  • Shtefan K. Fet,
  • Viktor A. Nikolaev

DOI
https://doi.org/10.15593/2224-9923/2017.3.10
Journal volume & issue
Vol. 16, no. 3
pp. 291 – 300

Abstract

Read online

Existing mine air heaters (MAH) that heat the air supplied into downcast shafts during the cold period are equipped with a heat channel. A part of the air from a MAH goes through a heat channel. Another part is sucked through a pit head by general depression created by a shaft main fan. That raises a problem of mixing of two air streams, which disturbs thermal regime in the shafts and could lead to violation of safety rules, in particular, create a breach of sealing of intertubular seals. Besides, there is a concern of energy saving during ventilation at underground mining enterprises. One of the reasons for energy efficiency reduce during air supply to a mine are external leaks appeared during ventilation by a suck method. The article presents proposed solution for both problems using air curtain. During air preparation in the cold period, it is proposed to place air curtain in an air downcast shafts above the junction of a heat channel and a shaft. That is done in order to prevent air infiltration (sucking) through a pit head. According to the paper air curtain should be used in the ventilation shaft to decrease outside air leakage in order to increase energy efficiency of a main fan performance. It is determined during mathematical modelling (in SolidWorks Flow Simulation software) of ventilation and air preparation that air curtain can increase efficiency of MAH and decrease energy consumption on ventilation.

Keywords