Decreasing the blood flow of non-compressible intra-abdominal organs with non-invasive transcutaneous electrical stimulation
Abstract
Abstract Non-invasive neuromodulation of non-compressible internal organs has significant potential for internal organ bleeding and blood-shift in aero/space medicine. The present study aims to investigate the potential influences of the non-invasive transcutaneous electrical nerve stimulation (TENS) on multiple non-compressible internal organs’ blood flow. Porcine animal model (n = 8) was randomized for a total of 48 neuromodulation sessions with two different TENS stimulation frequencies (80 Hz, 10 Hz) and a placebo stimulation. A combination of two different electrode configurations (Abdominal-only or Abdominal and hind limb) were also performed. Intraarterial blood flow measurements were taken during pre and post-stimulation periods at the left renal artery, common hepatic artery, and left coronary artery. Intracranial, and extracranial arterial blood flows were also assessed with digital subtraction angiography. TENS with abdominal-only electrode configurations at 10 Hz demonstrated significant reductions in average peak blood flow velocity (APV) of the common hepatic artery (p = 0.0233) and renal arteries (p = 0.0493). Arterial pressures (p = 0.0221) were also significantly lower when renal APV was reduced. The outcome of the present study emphasises the potential use of TENS in decreasing the blood flow of non-compressible internal organs when the correct combination of electrodes configuration and frequency is used.