Environments (Jul 2024)

Heated Aeration for Nitrite-Oxidizing Bacteria (NOB) Control in Anammox-Integrated Membrane-Aerated Biofilm Reactors (MABR)

  • Natalia Shiu,
  • Hui Guo,
  • Younggy Kim

DOI
https://doi.org/10.3390/environments11070155
Journal volume & issue
Vol. 11, no. 7
p. 155

Abstract

Read online

Nutrient removal in conventional wastewater treatment systems is expensive due to the high aeration costs. An alternative method for effective and sustainable nitrogen removal in wastewater treatment is anaerobic ammonium oxidation (Anammox) implemented with other innovative technologies, such as membrane-aerated biofilm reactors (MABRs). A major challenge associated with the Anammox process is effective control of nitrite-oxidizing bacteria (NOB). High temperature operation in wastewater treatment systems can promote Anammox bacterial growth and inhibit NOB activity. This research aims to investigate the feasibility of integrating Anammox processes with a lab-scale MABR and to examine the effects of high temperature aeration supplied to MABR systems on Anammox bacterial growth and NOB suppression. Experimental results indicate that the membrane’s air permeability was a critical parameter for the successful operation of Anammox-integrated MABR systems due to its influence on the system’s dissolved oxygen concentration (0.41 ± 0.39 mg O2/L). The ammonia removal by AOB and Anammox bacteria was determined to be 7.53 mg N/L·d (76.5%) and 2.12 mg N/L·d (23.5%), respectively. High temperature aeration in MABRs with the Anammox process shows a promising potential for improving energy consumption and sustainable nitrogen removal in wastewater treatment systems.

Keywords