Scientific Reports (Apr 2023)
Contact time and disinfectant formulation significantly impact the efficacies of disinfectant towelettes against Candida auris on hard, non-porous surfaces
Abstract
Abstract There has been an increase in Candida auris healthcare-associated infections, which result from cross-contamination from surfaces and equipment. In this study, we tested the efficacies of EPA-registered disinfectant towelettes products that are increasingly used for infection control against C. auris at a range of contact times following modifications to standard EPA protocol MB-33-00. Hydrogen peroxide (HP)-based disinfectant towelettes were more efficacious against C. auris than the quaternary ammonium chloride (QAC)-alcohol-based disinfectant towelettes irrespective of tested contact times. Thirty s contact time was significantly less effective in reducing C. auris compared to 1-, 2-, 3-, and 10-min contact times. However, there were no statistically significant differences in the level of disinfection among 1-min and longer contact times regardless of product chemistry. None of the products achieved a standard six-log10 reduction at any tested contact times. Overall, the HP-based disinfectant towelette was significantly more fungicidal than the QAC-alcohol-based disinfectant towelette. For all product types, 30 s contact time did not achieve the same level of disinfection as 1-min or longer contact times. Overall, disinfectant towelette efficacy is dependent upon product formulation and contact time.